Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 17(7)2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38612019

RESUMO

Additives such as nano-silica and fly ash are widely used in cement and concrete materials to improve the rheology of fresh cement and concrete and the performance of hardened materials and increase the sustainability of the cement and concrete industry by reducing the usage of Portland cement. Therefore, it is important to study the effect of these additives on the rheological behavior of fresh cement. In this paper, we study the pulsating Poiseuille flow of fresh cement in a horizontal pipe by considering two different additives and when they are combined (nano-silica, fly ash, combined nano-silica, and fly ash). To model the fresh cement suspension, we used a modified form of the power-law model to demonstrate the dependency of the cement viscosity on the shear rate and volume fraction of cement and the additive particles. The convection-diffusion equation was used to solve for the volume fraction. After solving the equations in the dimensionless forms, we conducted a parametric study to analyze the effects of nano-silica, fly ash, and combined nano-silica and fly ash additives on the velocity and volume fraction profiles of the cement suspension. According to the parametric study presented here, larger nano-silica content results in lower centerline velocity of the cement suspension and larger non-uniformity of the volume fraction. Compared to nano-silica, fly ash exhibits an opposite effect on the velocity. Larger fly ash content results in higher centerline velocity, while the effect of the fly ash on the volume fraction is not obvious. For cement suspension containing combined nano-silica and fly ash additives, nano-silica plays a dominant role in the flow behavior of the suspension. The findings of the study can help the design and operation of the pulsating flow of fresh cement mortars and concrete in the 3D printing industry.

2.
Materials (Basel) ; 16(19)2023 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-37834569

RESUMO

The dynamics of air (gas) bubbles in a column of cement slurry is examined numerically. The air injected at the bottom of a laboratory-scale column through a porous distributor plate spatially distributes and migrates as a swarm of bubbles throughout the slurry toward the freeboard. The two-phase system of the cement slurry and the air bubbles is modeled using the conservation equations of mass and linear momentum in the framework of the volume-of-fluid (VOF) approach. The cement slurry is modeled using the Herschel-Bulkley and Bingham fluid models. Results show that the mean Sauter diameter and the mean rise velocity of the bubbles decrease with the gas flow rate. Meanwhile, it is found that the rising of the bubbles is controlled by breakup events, along with relatively weak path instabilities of the bubbles resulting in relatively straight trajectories, independent of the gas flow rate. The extent of the yielded region appears larger for the Herschel-Bulkley model compared to the Bingham fluid model (by approximately 10%).

3.
Polymers (Basel) ; 14(18)2022 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-36146036

RESUMO

In this paper, we study the boundary-layer flow of a Herschel-Bulkley fluid due to a moving plate; this problem has been experimentally investigated by others, where the fluid was assumed to be Carbopol, which has similar properties to cement. The computational fluid dynamics finite volume method from the open-source toolbox/library OpenFOAM is used on structured quad grids to solve the mass and the linear momentum conservation equations using the solver "overInterDyMFoam" customized with non-Newtonian viscosity libraries. The governing equations are solved numerically by using regularization methods in the context of the overset meshing technique. The results indicate that there is a good comparison between the experimental data and the simulations. The boundary layer thicknesses are predicted within the uncertainties of the measurements. The simulations indicate strong sensitivities to the rheological properties of the fluid.

4.
Ann Biomed Eng ; 49(9): 2646-2658, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34401970

RESUMO

von Willebrand Factor is a mechano-sensitive protein circulating in blood that mediates platelet adhesion to subendothelial collagen and platelet aggregation at high shear rates. Its hemostatic function and thrombogenic effect, as well as susceptibility to enzymatic cleavage, are regulated by a conformational change from a collapsed globular state to a stretched state. Therefore, it is essential to account for the conformation of the vWF multimers when modeling vWF-mediated thrombosis or vWF degradation. We introduce a continuum model of vWF unfolding that is developed within the framework of our multi-constituent model of platelet-mediated thrombosis. The model considers two interconvertible vWF species corresponding to the collapsed and stretched conformational states. vWF unfolding takes place via two regimes: tumbling in simple shear and strong unfolding in flows with dominant extensional component. These two regimes were demonstrated in a Couette flow between parallel plates and an extensional flow in a cross-slot geometry. The vWF unfolding model was then verified in several microfluidic systems designed for inducing high-shear vWF-mediated thrombosis and screening for von Willebrand Disease. The model predicted high concentration of stretched vWF in key regions where occlusive thrombosis was observed experimentally. Strong unfolding caused by the extensional flow was limited to the center axis or middle plane of the channels, whereas vWF unfolding near the channel walls relied upon the shear tumbling mechanism. The continuum model of vWF unfolding presented in this work can be employed in numerical simulations of vWF-mediated thrombosis or vWF degradation in complex geometries. However, extending the model to 3-D arbitrary flows and turbulent flows will pose considerable challenges.


Assuntos
Modelos Biológicos , Desdobramento de Proteína , Fator de von Willebrand , Trombose
5.
J Biomech ; 121: 110397, 2021 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-33845357

RESUMO

Thromboembolic complications remain a central issue in management of patients on mechanical circulatory support. Despite the best practices employed in design and manufacturing of modern ventricular assist devices, complexity and modular nature of these systems often introduces internal steps and crevices in the flow path which can serve as nidus for thrombus formation. Thrombotic potential is influenced by multiple factors including the characteristics of the flow and surface chemistry of the biomaterial. This study explored these elements in the setting of blood flow over a micro-crevice using a multi-constituent numerical model of thrombosis. The simulations reproduced the platelet deposition patterns observed experimentally and elucidated the role of flow, shear rate, and surface chemistry in shaping the deposition. The results offer insights for design and operation of blood-contacting devices.


Assuntos
Coração Auxiliar , Tromboembolia , Trombose , Plaquetas , Coração Auxiliar/efeitos adversos , Hemodinâmica , Humanos , Estresse Mecânico , Trombose/etiologia
6.
J Comput Appl Math ; 3762020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34703076

RESUMO

In this paper, we numerically simulate the flow of blood in two benchmark problems: the flow in a sudden expansion channel and the flow through an idealized curved coronary artery with pulsatile inlet velocity. Blood is modeled as a suspension (a non-linear complex fluid) and the movement of the red blood cell (RBCs) is modeled by using a concentration flux equation. The viscosity of blood is obtained from experimental data. In the sudden expansion flow, the predicted velocity profiles for two different Reynolds numbers (based on the inlet velocity) agree well with the available experiments; furthermore, the numerical results also show that after the sudden expansion there exists a RBCs depletion region. For the second problem, the idealized curved coronary artery, it is found that the RBCs move towards and concentrate near the inner surface where the viscosity is higher and the shear stress lower; this phenomenon may be related to the atherosclerotic plaque formation which usually occurs on the inside surface of the arteries.

7.
Int J Eng Sci ; 1472020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34565829

RESUMO

This study was undertaken to develop a numerical/computational simulation of von Willebrand Factor (vWF) - mediated platelet shear activation and deposition in an idealized stenosis. Blood is treated as a multi-constituent mixture comprised of a linear fluid component and a porous solid component (thrombus). Chemical and biological species involved in coagulation are modeled using a system of coupled convection-reaction-diffusion (CRD) equations. This study considers the cumulative effect of shear stress (history) on platelet activation. The vWF activity is modeled as an enhancement function for the shear stress accumulation and is related to the experimentally-observed unfolding rate of vWF. A series of simulations were performed in an idealized stenosis in which the predicted platelets deposition agreed well with previous experimental observations spatially and temporally, including the reduction of platelet deposition with decreasing expansion angle. Further simulation indicated a direct relationship between vWF-mediated platelet deposition and degree of stenosis. Based on the success with these benchmark simulations, it is hoped that the model presented here may provide additional insight into vWF-mediated thrombosis and prove useful for the development of more hemo-compatible blood-wetted devices in the future.

8.
Int J Non Linear Mech ; 109: 32-39, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31447489

RESUMO

Motivated by the complex rheological behaviors observed in small/micro scale blood vessels, such as the Fahraeus effect, plasma-skimming, shear-thinning, etc., we develop a non-linear suspension model for blood. The viscosity is assumed to depend on the volume fraction (hematocrit) and the shear rate. The migration of the red blood cells (RBCs) is studied using a concentration flux equation. A parametric study with two representative problems, namely simple shear flow and a pressure driven flow demonstrate the ability of this reduced-order model to reproduce several key features of the two-fluid model (mixture theory approach), with much lower computational cost.

9.
Sci Rep ; 7: 42720, 2017 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-28218279

RESUMO

In this paper, we present a spatio-temporal mathematical model for simulating the formation and growth of a thrombus. Blood is treated as a multi-constituent mixture comprised of a linear fluid phase and a thrombus (solid) phase. The transport and reactions of 10 chemical and biological species are incorporated using a system of coupled convection-reaction-diffusion (CRD) equations to represent three processes in thrombus formation: initiation, propagation and stabilization. Computational fluid dynamic (CFD) simulations using the libraries of OpenFOAM were performed for two illustrative benchmark problems: in vivo thrombus growth in an injured blood vessel and in vitro thrombus deposition in micro-channels (1.5 mm × 1.6 mm × 0.1 mm) with small crevices (125 µm × 75 µm and 125 µm × 137 µm). For both problems, the simulated thrombus deposition agreed very well with experimental observations, both spatially and temporally. Based on the success with these two benchmark problems, which have very different flow conditions and biological environments, we believe that the current model will provide useful insight into the genesis of thrombosis in blood-wetted devices, and provide a tool for the design of less thrombogenic devices.


Assuntos
Cardiopatias/fisiopatologia , Trombose/fisiopatologia , Simulação por Computador , Humanos , Hidrodinâmica , Modelos Cardiovasculares
10.
Sci Rep ; 6: 38025, 2016 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-27905492

RESUMO

Continuous flow ventricular assist devices (cfVADs) provide a life-saving therapy for severe heart failure. However, in recent years, the incidence of device-related thrombosis (resulting in stroke, device-exchange surgery or premature death) has been increasing dramatically, which has alarmed both the medical community and the FDA. The objective of this study was to gain improved understanding of the initiation and progression of thrombosis in one of the most commonly used cfVADs, the Thoratec HeartMate II. A computational fluid dynamics simulation (CFD) was performed using our recently updated mathematical model of thrombosis. The patterns of deposition predicted by simulation agreed well with clinical observations. Furthermore, thrombus accumulation was found to increase with decreased flow rate, and can be completely suppressed by the application of anticoagulants and/or improvement of surface chemistry. To our knowledge, this is the first simulation to explicitly model the processes of platelet deposition and thrombus growth in a continuous flow blood pump and thereby replicate patterns of deposition observed clinically. The use of this simulation tool over a range of hemodynamic, hematological, and anticoagulation conditions could assist physicians to personalize clinical management to mitigate the risk of thrombosis. It may also contribute to the design of future VADs that are less thrombogenic.


Assuntos
Anticoagulantes/uso terapêutico , Coração Auxiliar/efeitos adversos , Trombose/tratamento farmacológico , Trombose/etiologia , Simulação por Computador , Feminino , Hemodinâmica , Humanos , Hidrodinâmica , Masculino , Fluxo Pulsátil , Propriedades de Superfície
11.
Artigo em Inglês | MEDLINE | ID: mdl-27761107

RESUMO

This study is motivated by the development of a blood cell filtration device for removal of malaria-infected, parasitized red blood cells (pRBCs). The blood was modeled as a multi-component fluid using the computational fluid dynamics discrete element method (CFD-DEM), wherein plasma was treated as a Newtonian fluid and the red blood cells (RBCs) were modeled as soft-sphere solid particles which move under the influence of drag, collisions with other RBCs, and a magnetic force. The CFD-DEM model was first validated by a comparison with experimental data from Han et al. 2006 (Han and Frazier 2006) involving a microfluidic magnetophoretic separator for paramagnetic deoxygenated blood cells. The computational model was then applied to a parametric study of a parallel-plate separator having hematocrit of 40% with a 10% of the RBCs as pRBCs. Specifically, we investigated the hypothesis of introducing an upstream constriction to the channel to divert the magnetic cells within the near-wall layer where the magnetic force is greatest. Simulations compared the efficacy of various geometries upon the stratification efficiency of the pRBCs. For a channel with nominal height of 100 µm, the addition of an upstream constriction of 80% improved the proportion of pRBCs retained adjacent to the magnetic wall (separation efficiency) by almost 2 fold, from 26% to 49%. Further addition of a downstream diffuser reduced remixing, hence improved separation efficiency to 72%. The constriction introduced a greater pressure drop (from 17 to 495 Pa), which should be considered when scaling-up this design for a clinical-sized system. Overall, the advantages of this design include its ability to accommodate physiological hematocrit and high throughput - which is critical for clinical implementation as a blood-filtration system.

12.
Int J Eng Sci ; 95: 49-59, 2015 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-26240438

RESUMO

It is known that in a vessel whose characteristic dimension (e.g., its diameter) is in the range of 20 to 500 microns, blood behaves as a non-Newtonian fluid, exhibiting complex phenomena, such as shear-thinning, stress relaxation, and also multi-component behaviors, such as the Fahraeus effect, plasma-skimming, etc. For describing these non-Newtonian and multi-component characteristics of blood, using the framework of mixture theory, a two-fluid model is applied, where the plasma is treated as a Newtonian fluid and the red blood cells (RBCs) are treated as shear-thinning fluid. A computational fluid dynamic (CFD) simulation incorporating the constitutive model was implemented using OpenFOAM® in which benchmark problems including a sudden expansion and various driven slots and crevices were studied numerically. The numerical results exhibited good agreement with the experimental observations with respect to both the velocity field and the volume fraction distribution of RBCs.

13.
Int J Eng Sci ; 76: 56-72, 2014 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-24791016

RESUMO

In this paper, we consider the two dimensional flow of blood in a rectangular microfluidic channel. We use Mixture Theory to treat this problem as a two-component system: One component is the red blood cells (RBCs) modeled as a generalized Reiner-Rivlin type fluid, which considers the effects of volume fraction (hematocrit) and influence of shear rate upon viscosity. The other component, plasma, is assumed to behave as a linear viscous fluid. A CFD solver based on OpenFOAM® was developed and employed to simulate a specific problem, namely blood flow in a two dimensional micro-channel, is studied. Finally to better understand this two-component flow system and the effects of the different parameters, the equations are made dimensionless and a parametric study is performed.

14.
Int J Non Linear Mech ; 47(5): 506-520, 2012 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-22611284

RESUMO

In this paper we use a modified form of the mixture theory developed by Massoudi and Rajagopal to study the blood flow in a simple geometry, namely flow between two plates. The blood is assumed to behave as a two-component mixture comprised of plasma and red blood cells (RBCs). The plasma is assumed to behave as a viscous fluid whereas the RBCs are given a granular-like structure where the viscosity also depends on the shear-rate.

15.
Appl Math Comput ; 218(12): 6841-6850, 2012 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-22345827

RESUMO

High gradient magnetic field separators have been widely used in a variety of biological applications. Recently, the use of magnetic separators to remove malaria-infected red blood cells (pRBCs) from blood circulation in patients with severe malaria has been proposed in a dialysis-like treatment. The capture efficiency of this process depends on many interrelated design variables and constraints such as magnetic pole array pitch, chamber height, and flow rate. In this paper, we model the malaria-infected RBCs (pRBCs) as paramagnetic particles suspended in a Newtonian fluid. Trajectories of the infected cells are numerically calculated inside a micro-channel exposed to a periodic magnetic field gradient. First-order stiff ordinary differential equations (ODEs) governing the trajectory of particles under periodic magnetic fields due to an array of wires are solved numerically using the 1(st) -5(th) order adaptive step Runge-Kutta solver. The numerical experiments show that in order to achieve a capture efficiency of 99% for the pRBCs it is required to have a longer length than 80 mm; this implies that in principle, using optimization techniques the length could be adjusted, i.e., shortened to achieve 99% capture efficiency of the pRBCs.

16.
Int J Eng Sci ; 48(11): 1325-1331, 2010 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-21318093

RESUMO

Computational prediction of blood damage has become a crucial tool for evaluating blood-wetted medical devices and pathological hemodynamics. A difficulty arises in predicting blood damage under turbulent flow conditions because the total stress is indeterminate. Common practice uses the Reynolds stress as an estimation of the total stress causing damage to the blood cells. This study investigates the error introduced by making this substitution, and further shows that energy dissipation is a more appropriate metric of blood trauma.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...